The CellTiter 96® Non-radioactive Cell Proliferation Assay is a collection of qualified reagents that provide a convenient method of determining viable cell number. The CellTiter 96® Assay is a modification of the MTT assay method described by Mosmann and incorporates several improvements to the method that address previous technical problems including: 1) serum protein precipitation caused by adding organic solvent; 2) interference by phenol red; 3) incomplete solubilization of the formazan crystals resulting in lower sensitivity; and 4) stability of the colored product.
The CellTiter 96® Assay is performed by adding a premixed, optimized Dye Solution to culture wells of a 96-well plate, usually containing various concentrations of growth factor or test substance. During a 4-hour incubation, living cells convert the MTT tetrazolium component of the Dye Solution into a formazan product. If you currently use a [3H]-thymidine incorporation assay, the addition of Dye Solution can be substituted for the pulse of radioactive thymidine at the time point in the assay when the pulse of [3H]-thymidine is usually added. The Solubilization/Stop Solution is then added to the culture wells to solubilize the formazan product, and the absorbance at 570nm is recorded using a 96-well plate reader. In addition, direct comparison between [3H]-thymidine incorporation and tetrazolium conversion have demonstrated less than a 5% difference between the two assays for determination of growth factor content of several samples.
Features and Benefits
Gain Sensitivity: Detect as few as 1,000 cells/well with a 96-well plate reader. Greater sensitivity than the neutral red assay procedure.
Use With a Variety of Cells: Assay mammalian, plant and yeast cells.
Non-Radioactive: Requires no scintillation cocktail or radioactive waste disposal.
Save Time: Perform the assay in a 96-well plate with no washing steps, no cell harvesting and no scintillation counting.
Convenient and Adapts to Your Needs: Requires no weighing or mixing of dye compounds and follows either a 4-hour or overnight protocol.
Specifications
Catalog Number:
What's in the box?
| Item | Part # | Size |
|---|---|---|
|
Solubilization Solution/Stop Mix |
G401A | 1 × 100ml |
|
Dye Solution |
G402A | 1 × 15ml |
SDS
Search for SDSCertificate of Analysis
Use Restrictions
For Research Use Only. Not for Use in Diagnostic Procedures.Storage Conditions
Store Dye Solution at –20°C and Solubilization/Stop Solution at room temperature.
What's in the box?
| Item | Part # | Size |
|---|---|---|
|
Solubilization Solution/Stop Mix |
G4101 | 1 × 500ml |
|
Dye Solution |
G4102 | 1 × 75ml |
SDS
Search for SDSCertificate of Analysis
Use Restrictions
For Research Use Only. Not for Use in Diagnostic Procedures.Storage Conditions
Store Dye Solution at –20°C and Solubilization/Stop Solution at room temperature.
Resources
No related resources available
Related Products
Similar Products
CellTiter-Glo® One Solution Assay
Gold standard method for determining cell viability based on quantitation of ATP.
G8461, G8462
CellTiter 96® AQueous One Solution Cell Proliferation Assay
A single-reagent (MTS), colorimetric method for determining cell viability.
G3582, G3580, G3581
CellTiter 96® AQueous Non-Radioactive Cell Proliferation Assay (MTS)
A homogeneous, colorimetric cell viability assay for determining the number of viable cells.
G5421, G5430, G5440
Lumit® Cell Proliferation Assay (Human Ki-67)
Easy add-mix-measure plate-based assay for tracking hKi-67 without washing steps or specialized detection equipment.
GC1000, GC1002, GC1001
Frequently Used With
Caspase-Glo® 3/7 Assay System
An easy-to-use, plate-based luminescent assay for detecting caspase-3/7 activity.
G8090, G8091, G8093, G8092
CytoTox-Fluorâ„¢ Cytotoxicity Assay
A single-reagent-addition, homogeneous, fluorescent assay that measures the relative number of dead cells in cell populations.
G9260, G9261, G9262
GloMax® Discover System
High-performance microplate reader for detecting luminescence, fluorescence and absorbance.
GM3000