CytoTox-Fluorâ„¢ Cytotoxicity Assay
The CytoTox-Fluor™ Cytotoxicity Assay is a single-reagent-addition, homogeneous, fluorescent assay that measures the relative number of dead cells in cell populations. The assay measures a distinct protease activity associated with cytotoxicity and uses a fluorogenic peptide substrate (bis-alanyl-alanyl-phenylalanyl-rhodamine 110; bis-AAF-R110) to measure "dead-cell activity," which has been released from cells that have lost membrane integrity. The bis-AAF-R110 substrate cannot cross the intact membrane of live cells and therefore gives no signal from live cells. The assay is designed to accommodate downstream multiplexing with several Promega luminescent assays or spectrally distinct fluorescent assay methods, such as assays to measure caspase activation, reporter gene expression or orthogonal measures of viability.
Features and Benefits
- Homogeneous, "add-mix-measure" protocol eliminates parallel plate processing and reduces cell culture costs.
- Multiplex the CytoTox-Fluor™ Assay with several Promega luminescent cell-based assays and get more data from every well.
- Data normalization for dead-cell number makes results more comparable well-to-well, plate-to-plate, day-to-day.
- Reduce assay variability and avoid the cumulative error associated with multistep protocols.
G9260 contains sufficient reagents for 100 assays at 100μl/assay in a 96-well format or 400 assays at 25μl/assay in a 384-well format. G9261 contains sufficient reagents for 500 assays at 100μl/assay in a 96-well format or 2,000 assays at 25μl/assay in 384-well format. G9262 contains sufficient reagents for 1,000 assays at 100μl/assay in a 96-well format or 4,000 assays at 25μl/assay in a 384-well format.
Protocols
Complete Protocol
Specifications
Catalog Number:
What's in the box?
| Item | Part # | Size |
|---|---|---|
|
bis-AAF-R110 Substrate |
G609A | 1 × 10μl |
|
Assay Buffer |
G610A | 1 × 10ml |
SDS
Search for SDSCertificate of Analysis
Use Restrictions
For Research Use Only. Not for Use in Diagnostic Procedures.Storage Conditions
What's in the box?
| Item | Part # | Size |
|---|---|---|
|
bis-AAF-R110 Substrate |
G609A | 5 × 10μl |
|
Assay Buffer |
G610A | 5 × 10ml |
SDS
Search for SDSCertificate of Analysis
Use Restrictions
For Research Use Only. Not for Use in Diagnostic Procedures.Storage Conditions
What's in the box?
| Item | Part # | Size |
|---|---|---|
|
bis-AAF-R110 Substrate |
G609B | 2 × 50μl |
|
Assay Buffer |
G610B | 2 × 50ml |
SDS
Search for SDSCertificate of Analysis
Use Restrictions
For Research Use Only. Not for Use in Diagnostic Procedures.Storage Conditions
Resources
No related resources available
Related Products
Similar Products
LDH-Gloâ„¢ Cytotoxicity Assay
Bioluminescence-based LDH assay for sensitive detection of cytotoxicity in samples low in cell number, including 3D microtissues.
J2380, J2381
CellTiter-Fluorâ„¢ Cell Viability Assay
A non-lytic, fluorescent cell viability assay with multiplex capability.
G6080, G6081, G6082
CytoTox-Gloâ„¢ Cytotoxicity Assay
Highly sensitive luminescent cytotoxicity assay that measures the relative number of dead cells.
G9290, G9291, G9292
CytoTox-ONEâ„¢ Homogeneous Membrane Integrity Assay
A homogeneous, LDH-based fluorometric method for quantifying non-viable cells.
G7890, G7891, G7892
Frequently Used With
CellTiter-Glo® Luminescent Cell Viability Assay
Determine the number of viable cells in culture based on quantitation of ATP present.
G7570, G7571, G7572, G7573
Caspase-Glo® 8 Assay Systems
Measure caspase-8 activity with this homogeneous, luminescent assay.
G8200, G8201, G8202
Caspase-Glo® 3/7 Assay System
An easy-to-use, plate-based luminescent assay for detecting caspase-3/7 activity.
G8090, G8091, G8093, G8092
GloMax® Discover System
High-performance microplate reader for detecting luminescence, fluorescence and absorbance.
GM3000